spring thimble pogo pin

How to troubleshoot spring machine probe problems?

source:pogo pin release time:2022-03-14 Article author:sznbone Popular:POGO PIN


  In the production process of the spring machine, the wire feeding is out of routine, resulting in irregular sample production. We have observed in daily production. Problems like this are caused by the failure of the probe in the spring machine. How can we eliminate the problem of the probe? Zhejiang Lixin Spring Machinery also gives guidance in this regard.

  In the production process of the computer spring machine, the feeding line is out of routine, which leads to the problem of irregular sample production. We have observed in daily production. Problems like this are caused by the failure of the probe in the spring machine. Question How can we eliminate the problem of the probe? Luoyang Xianheng CNC spring machine in Henan gives the following guidance

  1. Electrical signal failure: the auxiliary wire feeding stops when the probe does not touch the steel wire (maybe the electrical signal wire is not insulated from the machine), or the probe does not stop feeding when it touches the steel wire (the electrical signal wire may be open circuit). Then it is necessary to check whether the electrical signal of the control needle is normal, mainly whether the electrical signal line of the probe is insulated from the surrounding, or whether the electrical signal line is open circuit. (At this time, you can remove the probe and hold it in your hand. When the machine runs until the probe needs to work, touch the probe with the probe in your hand to see if the feeding line can stop immediately. If not, it is proved that the needle is controlled. work abnormally).

  2. Observe the working status of the screen analysis probe: observe the working status of the 1/0 interface signal light in the lower right corner of the screen when the probe is installed. If the probe senses the steel wire, it should be: the probe sticks out, the blue signal light on the left side of 1 is on; then the probe senses the steel wire, the light on the left side is off, and the yellow signal light on the right side is on. (It may be necessary to add a pause time T command before the cylinder retracts (S1-) action to see the yellow signal light on.